![]() ![]() If the self-test sequence determines there is a potential loss of protection the GFCI will need to take specific actions such as tripping or providing an indication to alert end users. The GFCI has internal parts that automatically conduct a test on regular intervals to ensure that the GFCI sensing and trip capabilities are intact. What does auto-monitoring or self-test mean? Leviton GFCIs protect against being reset unless they are properly wired, operating correctly, and connected to power. Simply connecting the wires exactly the same as they are on the older device may cause this reversal. You can diagnose this when you flip the breaker to reconnect power and the indicator light is green while the GFCI will not allow you to reset. This can easily be addressed by correcting the wiring. Take a look at the back of the device you are installing to note which side is the LINE and which side is the LOAD and attach the wires accordingly. If your GFCI does not reset after installation this is often the result of reversing the LINE and LOAD wires when installing. I don’t understand what the problem could be? GFCIs (Ground-Fault Circuit Interrupters) Frequently Asked Questions I just installed my GFCI and it isn’t working? I removed the old one from the wall and connected the wires exactly the same way as they were before. Compatible with all Decora devices and wallplates available in select Decora colors.Advanced electronics design provides superior resistance to electrical surges and over-voltages.Improved immunity to high-frequency noise reduces nuisance tripping.Trip threshold meets or exceeds UL requirements for tripping time. ![]() Withstands high torque and resists wire pullout.External back wire clamps provide visual indication of proper wire seating.Terminals allow for easy wiring options – back and side wire capable.Reduced depth makes it easier to install in any electrical box, even shallow ones.Electronics are designed to minimize any false triggers.Patented Lockout Action prevents reset if GFCI is damaged and cannot respond to a ground fault.Status Indicator Light provides simple, intuitive feedback on power and protection status as well as indication of line/load reversal.Auto adapts and shifts to more frequent testing if potential problem is detected.Auto-monitoring exceeds the UL requirement.On initial power up, tests the GFCI within 3 seconds.Provides continuous ground fault protection – detects and trips on actual ground fault even when self-test is being conducted. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |